Compact
CPUs |
|
Technology
CPU |
| |
CPU
314C-2 PtP |
CPU
314C-2 DP |
CPU
317T-2DP |
| Start
of delivery |
|
|
4th
quarter 2003(New) |
| Main
memory / instructions |
48
Kbyte/16 K |
48
Kbyte/16 K |
512
Kbyte/170 K |
| Load
memory |
64
Kbyte to 8 Mbyte through MMC
|
64
Kbyte to 8 Mbyte through MMC |
| Backup |
all
blocks through MMC |
all
blocks through MMC |
Processing
times
- Bit operations
- Word
operations/fixed point
a./floating point arithmetic
|
|
|
|
Bit
memories/timers/counters
- Bit memories
- S7 timers/counters
- IEC timer/counters
|
256 byte
256/256
yes |
256 byte
256/256
yes |
4096 byte
512/512
yes |
Number
of blocks
- Number of loadable blocks
- Ranger of numbers
|
1024
512 FC. 512 FB, 511 DB |
1024
512 FC, 512 FB, 511 DB |
2048
2048 FC, 2048 FB, 2047 DB |
Program
processing
|
free
cycle (OB 1), real-time controlled (OB 10), delay
alarm (OB 20), time-triggered (OB 35), interrupt-
triggered (OB 40), restart (OB 100, 102), asynchronous
error (OB 80, 82, 85, 87), synchronous error
(OB 121, 122), station failure/restoration (OB 86,
not with CPU 314C-2PtP), DPV1 restart (OB 55-57,
only with CPU 317T-2 DP) |
Address
ranges
- I/O address area
- I/O process image
- Digital channels (central)
- Analog channels (central)
|
1024/1024 byte
128/128 byte
1016
253 |
1024/1024 byte
128/128 byte
1016
253 |
8192/8192 byte
256/256 byte
1024
256 |
| Expansions
|
max. 4
8 |
max. 4
8 |
1
8 |
DP
interfaces
- Number of DP master systems int./CP 342-5
- Equidistant
- Activation/deactivation of slaves
- Transmission speed
- No. of DP slaves per station
- Lateral communication
|
–
–
–
–
–
– |
1/1
yes
yes
12 Mbit/s
32
yes |
2/2
yes
yes
12 Mbit/s
124
yes |
| Integrated
functions |
- Counters:
4 incremental encoders 24 V/60 kHz
- Pulse
outputs: 4 channel pulse-width modulation max.
2.5 kHz
-
Frequency measurement: 4 channels max. 60 kHz
-
Controlled positioning: SFB for positioning
1 axis using 2 DA, AA
-
Integrated FBs “loop control”: PID
controller
|
- Gear
and curve synchronism
-
Travel to fixed stop
-
Print mark control via measuring probes
-
Parth or time-controlled cam switching
-
Controlled positioning
|
Integrated
I/Os
-
Digital inputs
-
Digital outputs
-
Analog inputs
-
Analog outputs
|
- 24;
24 V DC; all channels can be used for process
alarms
- 16;
24 V DC, 0.5 A
- 4:
± 10 V. 0..10 V, ± 20 mA, 0/4..20
mA; 1: 0..600 m PT100
- 2:
±10 V, 0-10 V, ± 20mA, 0/4-20
mA
|
4;
24 V DC;
for probe evaluation
8; 24 V DC; 0.6 A; for fast cam
switching functions
–
–
PtP interface
· Protocol driver
RS485/422
3964 (R), RK512, ASCII
–
–
–
– |
| |
|
|
|
| Dimensions
(mm) |
120
x 125 x 130 |
120
x 125 x 130 |
160
x 125 x 130 |
| Required
front connector |
2
x 40 pin |
1
x 40 pin |
1
x 40 pin |
Order
No. group
|
6ES7314-6BF..
|
6ES7314-6CF..
|
6ES7317-6TJ.. |
 |