Back to Products
 
 
 

 


Click here for brief specification of each category in S7-300 CPU spectrum:

Standard CPUs
Failsafe CPUs
Compact CPUs
Technology CPU


<<
Back to S7-300 Family



Technology CPU


  Compact CPUs   Technology CPU 
  CPU 314C-2 PtP CPU 314C-2 DP CPU 317T-2DP
Start of delivery     4th quarter 2003(New)
Main memory / instructions 48 Kbyte/16 K 48 Kbyte/16 K 512 Kbyte/170 K
Load memory

64 Kbyte to 8 Mbyte through MMC

64 Kbyte to 8 Mbyte through MMC
Backup all blocks through MMC all blocks through MMC
Processing times
  • Bit operations
  • Word operations/fixed point
    a./floating point arithmetic

  • 0.1µs
  • 0.2/2/6µs
  • 0.1µs
  • 0.2/2/6µs
  • 0.1µs
  • 0.1/0.2/2µs
Bit memories/timers/counters
  • Bit memories
  • S7 timers/counters
  • IEC timer/counters


256 byte
256/256
yes


256 byte
256/256
yes


4096 byte
512/512
yes
Number of blocks
  • Number of loadable blocks
  • Ranger of numbers


1024
512 FC. 512 FB, 511 DB


1024
512 FC, 512 FB, 511 DB


2048
2048 FC, 2048 FB, 2047 DB
Program processing
free cycle (OB 1), real-time controlled (OB 10), delay alarm (OB 20), time-triggered (OB 35), interrupt-
triggered (OB 40), restart (OB 100, 102), asynchronous error (OB 80, 82, 85, 87), synchronous error
(OB 121, 122), station failure/restoration (OB 86, not with CPU 314C-2PtP), DPV1 restart (OB 55-57, only with CPU 317T-2 DP)
Address ranges
  • I/O address area
  • I/O process image
  • Digital channels (central)
  • Analog channels (central)

1024/1024 byte
128/128 byte
1016
253

1024/1024 byte
128/128 byte
1016
253

8192/8192 byte
256/256 byte
1024
256
Expansions
  • Racks
  • Modules per rack

max. 4
8

max. 4
8


1
8
 
DP interfaces
  • Number of DP master systems int./CP 342-5
  • Equidistant
  • Activation/deactivation of slaves
  • Transmission speed
  • No. of DP slaves per station
  • Lateral communication










1/1

yes
yes
12 Mbit/s
32
yes


2/2

yes
yes
12 Mbit/s
124
yes
 
Integrated functions
  • Counters: 4 incremental encoders 24 V/60 kHz
  • Pulse outputs: 4 channel pulse-width modulation max. 2.5 kHz
  • Frequency measurement: 4 channels max. 60 kHz
  • Controlled positioning: SFB for positioning 1 axis using 2 DA, AA
  • Integrated FBs “loop control”: PID controller
  • Gear and curve synchronism
  • Travel to fixed stop
  • Print mark control via measuring probes
  • Parth or time-controlled cam switching
  • Controlled positioning

Integrated I/Os

  • Digital inputs
  • Digital outputs
  • Analog inputs
  • Analog outputs

     

  • 24; 24 V DC; all channels can be used for process alarms
  • 16; 24 V DC, 0.5 A
  • 4: ± 10 V. 0..10 V, ± 20 mA, 0/4..20 mA; 1: 0..600 m PT100
  • 2: ±10 V, 0-10 V, ± 20mA, 0/4-20 mA
4; 24 V DC;
for probe evaluation
8; 24 V DC; 0.6 A; for fast cam
switching functions


PtP interface
· Protocol driver
RS485/422
3964 (R), RK512, ASCII



       
Dimensions (mm) 120 x 125 x 130   120 x 125 x 130   160 x 125 x 130 
Required front connector 2 x 40 pin 1 x 40 pin 1 x 40 pin
Order No. group
6ES7314-6BF.. 6ES7314-6CF.. 6ES7317-6TJ..

 

TOP PAGE

 

 

SIMATIC S7-300 Product Overview- Siemens Brochure
SIMATIC S7-300 Page Techonology CPU - Siemens Website
Siemens AG Automation and Drive (A&D) - Search Page for any of Siemens A&D products including FAQ, manual, download software tools etc.
SIMATIC Technical Documents Page - Website Siemens
 
Home | Vision | Milestones | Mailing List | Inquiry Form | Site Map | Links | Search | Job Vacancy
Machine Tool Automation | Production Machine Automation | P r o d u c t s | Project References
Customer Support | Download Page | N e w s | Contact Us

Copyright © 2004 CNC Design Pty Ltd. All rights reserved.